1. Scope and application of this document
This document contains requirements for a GMP+ certified company that processes critical feed additives and/or veterinary medicinal products, regarding
- the control of residues
- homogeneity.
2. Control of residues
2.1. Application of HACCP principles
A GMP+ certified company must define control measures to ensure that residues of critical feed additives and veterinary medicinal products do not exceed the limits laid down in Appendix 2.
Note: Possible and often used control measures are:
- Use of dedicated production and transport lines within a location
- Flushing/sequencing: see chapter 2.2
- Physical clean-out
- A combination of above-mentioned control measure(s).
Any measure or combination of measures to control the residues of critical feed additives / veterinary medicinal products must be validated:
- Validation of control measures which are applied on non-dedicated production/transport lines, must involve analysing at least 2 representative samples of feed for which residue limits are laid down in Appendix 2.
- When using dedicated production/transport lines, the company must demonstrate and document that residue limits, laid down in Appendix 2, are not exceeded.
The ongoing effectiveness of the control measures must be monitored at least quarterly. This is done by analysing, in a representative sample, the residue level of the processed critical feed additive or veterinary medicinal product.
If the company processes several types of critical feed additives and/or veterinary medicinal products, these must be analysed in turn.
Nuttige tip
Suppose you are processing 6 different coccidiostats. You include all 6 of these coccidiostats in the analysis schedule: in the 1st quarter you analyse for residues of coccidiostat A, in the second quarter for residues of coccidiostat B, etc. After 6 quarters (1.5 years) you have analysed all coccidiostats on residues and start again with an analysis for residues of coccidiostat A.
Analysis must be carried out by a laboratory that is approved as such (see for this TS1.2 Purchase).
2.2. Additional requirements for flushing
A commonly used control measure is to ‘clean’ the production installation by flushing it with feed, right after the production of a feed in which a critical feed additive or a veterinary medicinal product is processed.
The following conditions apply:
- Flushing must be done with a defined, validated volume of a feed. This flushing batch size matches the batch size used in normal daily production, unless the company demonstrates, based on site-specific research, that a smaller batch size provides sufficient cleaning. Validation must include analysis of at least 2 representative samples.
- A feed material, used for flushing, must be carefully handled and processed afterwards, so that all legal regulations are met and feed safety issues are avoided. This must be supported by a hazard analysis.
- When placed on the market, the feed used for flushing, must comply with applicable legislation. In any case, the levels of critical feed additives/veterinary medicinal products (Appendix 2) must not be exceeded.
- In case the installation is flushed via a calculated production sequence based on measured carry-over percentage, then the periodical verification of the effectiveness (as required in chapter 2.1) may be reduced by 50%, provided that the method used to measure the carry-over complies with the criteria in Appendix 1.
- When choosing the flushing method, the company takes into account national feed legislation including the interpretation by the competent authorities.
Any deviation from the above conditions must be justified and documented.
Nuttige tip
Flushing via a calculated production sequence based on measured carry-over percentage is preferable
3. Homogeneity
Every mixer, in which dry mixtures with critical feed additives or veterinary medicinal products are produced, must be tested to demonstrate its effectiveness regarding homogeneity. The method used to measure the homogeneity must comply with the criteria in Appendix 1.
Depending on the method used, the results must be interpreted based on the limits in the next tables:
Determination of homogeneity by means of direct methods
Probability p | Assessment |
p ≤ 1% | Insufficient |
1% < p ˂ 5% | Probably significant deviation. No unambiguous statement can be made. The test must be repeated. |
P ≥ 5% | Good homogeneity |
Determination of homogeneity by means of indirect methods
Coefficient of variation CV | Assessment |
CV ≤ 8% | Good homogeneity |
8% < CV ˂ 12% | Acceptable homogeneity |
CV ≥ 12% | Insufficient |
If the homogeneity of the mixture is assessed as insufficient, the GMP+ certified company must carry out a root cause analysis, take corrective measures and perform a new homogeneity test in order to verify that the measures taken are effective in achieving a sufficient homogeneity.
Appendix 1: Criteria for measurement of carry-over and homogeneity
The table below gives minimum criteria for measuring carry-over and homogeneity. There may be some overlap between methods to measure carry over and homogeneity. This is why a lot of companies combine the measurement of carry over and homogeneity. Note that combining of these both measurements is not an obligation.
In some countries, special requirements to measure the carry-over level and homogeneity are laid down in legislation. Those measurement methods are accepted.
Explanation table below:
In some cases there are different criteria mentioned (e.g. Measurement method), but in case the criteria is the same for both carry-over and homogeneity, there is no separation in the table (e.g. Tracer).
| Homogeneity | Carry-over |
Measurement method See helpful tip 1, 2 and 3 |
|
|
Frequency | The carry-over and homogeneity must be measured at first use of an installation and re-measured after significant modification of the installation. | |
Further, at least every 4 years | Further, at least every 2 years. | |
Tracer See helpful tip 1 |
Note: Macro elements (e.g. Ca, Na) are not allowed to measure carry-over and homogeneity of mixtures containing critical feed additives / veterinary medicinal products. | |
Sampling and analysing |
| |
|
| |
Process parameters |
|
|
Reporting |
|
Nuttige tip
Use as much as possible one type of tracer/method to make better comparisons with previous tests.
Nuttige tip
The tracer must follow the same route as the critical feed additives and / or veterinary medicinal product through the installation.
Nuttige tip
GMP+ Support documents contain more detailed descriptions of methods for measuring carry-over and homogeneity (see S9.14 Methods for measuring carry-over & homogeneity of critical feed additives and veterinary medicinal products).
Appendix 2: Residue limits
The next table below shows the residue limits for critical feed additives / veterinary medicinal products.
Critical Feed additives (Coccidiostats) | Feed | Maximum content in mg/kg (ppm) relative to a feed with a moisture content of 12 % |
Lasalocid A sodium | Feed materials | 1,25 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Lasalocid A sodium is not authorised. | () | |
Narasin | Feed materials | 0,7 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Narasin is not authorised. | () | |
Salinomycin sodium | Feed materials | 0,7 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Salinomycin sodium is not authorised. | () | |
Monensin sodium | Feed materials | 1,25 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Monensin sodium is not authorised. | () | |
Semduramicin sodium | Feed materials | 0,25 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Semduramicin sodium is not authorised. | () | |
Maduramicin ammonium alpha | Feed materials | 0,05 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Maduramicin ammonium alpha is not authorised. | () | |
Robenidine hydro- chloride | Feed materials | 0,7 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Robenidine hydrochloride is not authorised. | () | |
Decoquinate | Feed materials | 0,4 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Decoquinate is not authorised | () | |
Halofuginone hydro-bromide | Feed materials | 0,03 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Halofuginone hydro bromide is not authorised. | () | |
Nicarbazin | Feed materials | 1,25 |
Compound feed for:
| | |
Premixtures for use in feed in which the use of Nicarbazin (in combination with Narasin) is not authorised. | () | |
Diclazuril | Feed materials | 0,01 |
Compound feed for:
| 0,01 | |
Premixtures for use in feed in which the use of Diclazuril is not authorised. | () | |
For other critical feed additives | Feed | Max. Percentage (%) |
| All non-target feed for food producing animals | 1% of the max. content, which is approved to mix in feed. () |
| All other non-target feed | 3% of the max. content, which is approved to mix in feed () |
Veterinary medicinal products () | Feed | Max. Percentage (%) |
| All non-target feed | 1 % of the max. content which is prescribed to mix in feed () |
Feed Support Products
That was a lot of information to digest and one might ask, what is the next step? Luckily we can offer support for the GMP+ Community when doing this. We provide support by means of various tools and guidances but as each company has a shared responsibility to feed safety, and therefor tailor-made solutions cannot be offered. However, we do help by explaining requirements and provide background information about the requirements.
We have developed various supporting materials for the GMP+ Community. These include various tools, ranging from Frequently Asked Questions (FAQ) lists to webinars and events.
Supporting materials related to this document (Guidelines and FAQ’s)
We have made documents available which give guidance to the GMP+ requirements as laid down in the module GMP+ FSA and GMP+ FRA. These documents give examples, answers to frequently asked questions or background information.